Mini Compact Terminal SCTMi
Intelligent. Compact. Flexible.
Flexibility, optimization of production processes, and continuous energy and process control are the challenges facing future automation. To meet these requirements, powerful, flexible and energy-efficient vacuum systems are needed. Our solution for this is the mini compact terminal SCTMi: a compact unit consisting of several vacuum generators that enables different parts to be handled simultaneously and independently with just one vacuum system.
Modular design with different, individually controllable vacuum circuits for handling different workpieces
Minimized integration and service costs thanks to central compressed air and power supply (24 V) for up to 16 mini compact ejectors
Use in limited spaces due to very small footprint and low weight
Reduction of compressed air consumption up to 80% thanks to automatic air saving function and intelligent condition monitoring function
Your Individual Configuration
The mini compact terminals SCTMi offer the flexibility to design the handling process entirely according to your needs. Thanks to innovative configurators, our sales staff can create a custom-made solution for you in no time at all.
In addition to an offer for your individual product, you will also receive a CAD model.
Request your personal configuration now and contact us!

Design

- Bus module with NFC interface (1) with central intelligence for condition monitoring and switching status display for each ejector
- Visual status indicator (2) for suction and blow-off valve
- Central compressed air or vacuum connection (for valve function) (3) as push-in in one direction
- Up to 16 ejectors (4), freely selectable according to nozzle size and type, NO/NC/IMP incl. automatic air saving function. Also as a valve function for switching an existing vacuum that is generated electrically, for example
- Flexible mounting options (5) allow for integration directly onto the gripper or onto moving axes
Ordering information
Product code
Similar to a part number, the product code is used to uniquely identify product configurations at Schmalz. The product code can be found on the product label or on the quotation or order. Do you have questions about your product or would you like to order a configuration again? Then please have this key ready when you contact Schmalz.
| Code | Type |
|---|---|
| SCTMI | SCTMi |
| Code | Type |
|---|---|
| IOL | IO-Link |
| EIP | EthernetIP |
| ECT | EtherCat |
| PNT | ProfiNet |
| Code | Type |
|---|---|
| E + number | Number of ejectors |
| V + number | Number of valves |
| Code | Type |
|---|---|
| ABC00001C | Individual configuration code |
Ordering information
| Nozzle size | Suction valve | Blow-off valve | Communication | Vacuum connection | Number of modules |
|---|---|---|---|---|---|
|
03 |
NO / NC / IMP |
NC |
IOL / EIP / PNT / ECT |
4mm OD hose |
1...16 |
|
05 |
NO / NC / IMP |
NC |
IOL / EIP / PNT / ECT |
4mm OD hose |
1...16 |
|
07 |
NO / NC / IMP |
NC |
IOL / EIP / PNT / ECT |
4mm OD hose |
1...16 |
|
10 |
NO / NC / IMP |
NC |
IOL / EIP / PNT / ECT |
6mm OD hose |
1...16 |
|
12 |
NO / NC / IMP |
NC |
IOL / EIP / PNT / ECT |
6mm OD hose |
1...16 |
|
EV |
NO / NC / IMP |
NC |
IOL / EIP / PNT / ECT |
6mm OD hose |
1...16 |
Ejectors (03/05/07/10/12) cannot be combined with vacuum valves (EV).
A maximum of 4 different ejector types can be selected.
Each ejector type has an integrated power blow-off function.
Technical Data
Technical data mini compact terminal SCTMi
| Type | Temperature [°C] | Pressure range (operating pressure) [bar] | Electrical connection | Communication | Valve position |
|---|---|---|---|---|---|
| SCTMi | 0...50 | 2...6 | M12 connector, 5-pin |
IO-Link Class B Ethernet ProfiNet, EtherCAT, EtherNet/IP |
Normally open (NO) Normally closed (NC) Bistable (IMP) |
Technical data compact ejectors SCPMt
| Type | Nozzle | Vacuum % | Suction rate m³/h | Suction rate l/min | Air consumption m³/h | Air consumption l/min | Blow-off volume flow l/min |
|---|---|---|---|---|---|---|---|
| SCPMt-03 | 03 | 87 | 0.132 | 2.2 | 0.21 | 3.5 | 55 |
| SCPMt-05 | 05 | 87 | 0.45 | 7.5 | 0.54 | 9 | 55 |
| SCPMt-07 | 07 | 87 | 0.9 | 15 | 1.32 | 22 | 55 |
| SCPMt-10 | 10 | 87 | 1.68 | 28 | 2.7 | 45 | 55 |
| SCPMt-12 | 12 | 92 | 1.8 | 30 | 4.56 | 76 | 55 |
All values refer to an inlet pressure of 4.5 bar.
| Type | Nominal width | Nominal flow @100mbar | Maximum flow @500mbar | Blow-off volume flow @4.5bar inlet pressure |
|---|---|---|---|---|
| SCPMti-EV | 1.8 | 17.5 l/min | 34 l/min | 55 l/min |
Performance Data
| 2 | 2.5 | 3 | 3.5 | 4 | 4.5 | 5 | 5.5 | 6 | |
|---|---|---|---|---|---|---|---|---|---|
| 0.3 / 0.5 / 0.7 mm | 416.00 | 512.00 | 711.00 | 866.00 | 880.00 | 875.00 | 860.00 | 850.00 | 845.00 |
| 1.0 mm | 350.00 | 416.00 | 512.00 | 725.00 | 866.00 | 880.00 | 870.00 | 860.00 | 850.00 |
| 1.2 mm | 330.00 | 460.00 | 610.00 | 740.00 | 850.00 | 922.00 | 930.00 | 927.00 | 925.00 |
| 0 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | |
|---|---|---|---|---|---|---|---|---|---|
| 0.3 mm | 0.00 | 1.60 | 3.20 | 5.60 | 7.90 | 11.10 | 15.00 | 24.00 | 48.00 |
| 0.5 mm | 0.00 | 0.76 | 1.51 | 2.65 | 3.78 | 5.29 | 8.00 | 14.00 | 26.60 |
| 0.7 mm | 0.00 | 0.42 | 0.84 | 1.47 | 2.10 | 2.94 | 5.00 | 8.40 | 14.00 |
| 1.0 mm | 0.00 | 0.18 | 0.38 | 0.60 | 0.90 | 1.10 | 2.00 | 3.10 | 4.40 |
| 1.2 mm | 0.00 | 0.18 | 0.38 | 0.60 | 0.90 | 1.10 | 2.00 | 3.10 | 4.40 |
| 0 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 | |
|---|---|---|---|---|---|---|---|---|---|---|
| 0.3 mm | 2.50 | 2.00 | 1.70 | 1.40 | 1.20 | 0.90 | 0.70 | 0.50 | 0.20 | 0.00 |
| 0.5 mm | 6.50 | 5.60 | 4.50 | 3.60 | 2.70 | 2.00 | 1.40 | 1.00 | 0.50 | 0.00 |
| 0.7 mm | 15.00 | 12.00 | 10.00 | 8.00 | 6.00 | 4.50 | 3.30 | 2.00 | 1.00 | 0.00 |
| 1.0 mm | 30.00 | 26.00 | 23.00 | 20.50 | 17.80 | 13.50 | 10.50 | 7.30 | 3.70 | 0.00 |
| 1.2 mm | 30.00 | 26.00 | 23.00 | 20.50 | 17.80 | 13.50 | 10.50 | 7.30 | 3.70 | 0.00 |
Documentation
The matching documentation for this product is available in this section.
| Documents | Language |
|---|---|
| English | |
| English |
Software
The matching software for this product is available in this section.
| Software | Language |
|---|---|
| English |
Functional descriptions
.jpg)
Near Field Communication (NFC)
- Safe communication through an energy-neutral point-to-point connection
- Visible data: In addition to static data, such as serial numbers, dynamic process data, such as switching points, can also be read out
- Parameterization option: The SCTMi can also be parameterized from a smartphone via an app
%20-%20Kopie.jpg)
Industry 4.0 compatible networking
- Recorded data is visible and usable up to the control level, enabling bidirectional parameterization and diagnostics in all common fieldbus systems
- Condition monitoring increases system availability through detailed condition analysis and fault detection
- Predictive maintenance enables predictive maintenance to increase the performance of gripping systems
- Energy monitoring enables energy monitoring of vacuum systems to optimize energy consumption
%20-%20Kopie.jpg)
Integrated electronic sub-bus system
- Electronic control possible via a single cable
- Continuous data communication via IO-Link and Near Field Communication (NFC)
- All ejectors can be programmed and controlled separately
%20-%20Kopie.jpg)
Automatic air saving function
- Switching off the suction function when a safe vacuum value is reached until the next cycle, or when the vacuum falls below the safe vacuum value
- Different settings and air-saving settings programmable for each ejector
- Reduction of compressed air consumption by up to 80%
- Visual feedback of valve control via LEDs
%20-%20Kopie.jpg)
Terminal with external vacuum supply
- Operation with external vacuum supply (e.g. central vacuum pump)
- Central vacuum can be divided into up to 16 individual circuits
- Use as a valve with IO-Link or fieldbus functions and condition monitoring
- Pneumatic pilot control for fast switching cycles
Integration
Simplified integration into the control level
(1) Conventional control of individual ejectors with high wiring effort for power and compressed air
(2) Control via compact terminal SCTMi with central connectors for compressed air, communication (IO-Link) or power
(3) Connection of the compact terminal SCTMi via Profinet / EtherCAT / Ethernet/IP
Products
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT
- NEW
- EFFICIENT